<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Power Transformers Blog - Expert Safety and Usage Info</title>
	<atom:link href="http://www.powertransformersblog.com/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.powertransformersblog.com</link>
	<description>by MIDWEST Electrical Testing, Milwaukee Wisconsin</description>
	<lastBuildDate>Wed, 04 Jan 2012 19:23:37 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.2.1</generator>
		<item>
		<title>Don’t Sell Rental Transformers</title>
		<link>http://www.powertransformersblog.com/2012/01/don%e2%80%99t-sell-rental-transformers/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=don%25e2%2580%2599t-sell-rental-transformers</link>
		<comments>http://www.powertransformersblog.com/2012/01/don%e2%80%99t-sell-rental-transformers/#comments</comments>
		<pubDate>Wed, 04 Jan 2012 19:19:19 +0000</pubDate>
		<dc:creator>MIDWEST</dc:creator>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[High Voltage Cables]]></category>
		<category><![CDATA[High Votlage Fused Switch]]></category>
		<category><![CDATA[Lightning Arrestors]]></category>
		<category><![CDATA[Low Voltage Cables]]></category>
		<category><![CDATA[Rent A Transformer]]></category>
		<category><![CDATA[Rental Pad Mount Power Transformer]]></category>
		<category><![CDATA[Rental Power Transformers]]></category>
		<category><![CDATA[rental transformers]]></category>
		<category><![CDATA[Temporary Equipment]]></category>

		<guid isPermaLink="false">http://www.powertransformersblog.com/?p=205</guid>
		<description><![CDATA[MIDWESTwas recently asked again why we don’t sell some of our rental transformers. This is a question often asked after power has been restored as fast as possible using temporary equipment instead of permanent repair involving a long time delay.  There are many reasons we try not to sell some of our rental power transformers. [...]]]></description>
			<content:encoded><![CDATA[<p><a title="MIDWEST's Offical Web Site" href="http://www.swgr.com/store/Rental-Transformer-Home.aspx"><img class="alignleft size-full wp-image-206" title="Rental Transformers Available at MIDWEST - www.swgr.com" src="http://www.powertransformersblog.com/wp-content/uploads/2012/01/rental-transformers.bmp" alt="Rental Transformers Available at MIDWEST - www.swgr.com" />MIDWEST</a>was recently asked again why we don’t sell some of our <a title="Rental Transformers available from MIDWEST" href="http://www.swgr.com/store/Rental-Transformer-Home.aspx">rental transformers</a>. This is a question often asked after power has been restored as fast as possible using <a title="Temporary Equipment Available For Rent at www.swgr.com" href="http://www.swgr.com/store/Rental-Transformer-Home.aspx">temporary equipment</a> instead of permanent repair involving a long time delay.  There are many reasons we try not to sell some of our <a title="Rental Power Transformers Available at MIDWEST - www.swgr.com" href="http://www.swgr.com/store/Rental-Transformer-Home.aspx">rental power transformers</a>. The <a title="Transformers For Sale by MIDWEST" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">transformer</a> may have an attached high voltage fused switch with lightning arrestors and cabling from the switch to the transformer already installed. A <a title="Rental Pad Mount Power Transformers Available at MIDWEST" href="http://www.swgr.com/store/Rental-Transformer-Home.aspx">rental pad mount power transformer</a> may be mounted on a skid and already have openings for conduit for the high voltage cables and for the temporary low voltage cables. There may be a main <a title="Circuit Breakers For Sale" href="http://www.swgr.com/store/circuit-breakers/molded-case/home.aspx">breaker</a> already mounted on the secondary. Some rentals have unusual voltages or many voltage taps not found on typical power transformers, making them much more valuable as a rental than for permanent installation. Some <a title="Transformers For Sale by MIDWEST" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">transformers </a>are too old to justify the cost of permanent installation. Some may have unusual primary or secondary physical configurations that are okay for a temporary transformer installation, but too difficult or expensive for permanent installation. Older transformers are physically much larger than same kva and voltage <a title="New Power Transfomers For Sale by MIDWEST" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">new power transformers</a>, which may make the installation of the older rental power transformer not practical or too expensive. Most of all, many requests to <a title="Rent A Transformer From MIDWEST" href="http://www.swgr.com/store/Rental-Transformer-Home.aspx">rent a transformer</a>, are an urgent need to get power back up as fast as possible, which frequently means temporarily. Then the owner can more calmly figure out what they want for permanent repair, considering cost and future needs.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.powertransformersblog.com/2012/01/don%e2%80%99t-sell-rental-transformers/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Technician’s Choice, Oil Filled Power Transformer versus Dry Type</title>
		<link>http://www.powertransformersblog.com/2011/09/technician%e2%80%99s-choice-oil-filled-power-transformer-versus-dry-type/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=technician%25e2%2580%2599s-choice-oil-filled-power-transformer-versus-dry-type</link>
		<comments>http://www.powertransformersblog.com/2011/09/technician%e2%80%99s-choice-oil-filled-power-transformer-versus-dry-type/#comments</comments>
		<pubDate>Thu, 15 Sep 2011 18:59:19 +0000</pubDate>
		<dc:creator>MIDWEST</dc:creator>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[2000 Kva Dry Transformer]]></category>
		<category><![CDATA[2000 KVA Oil Filled Substation Power Transformer]]></category>
		<category><![CDATA[Combustible Gas-in-Oil Tests]]></category>
		<category><![CDATA[dielectric fluid]]></category>
		<category><![CDATA[Dielectric Fluid Tests]]></category>
		<category><![CDATA[dry type transformers]]></category>
		<category><![CDATA[Electrical Power Engineers]]></category>
		<category><![CDATA[Engineering Technician]]></category>
		<category><![CDATA[Field Service]]></category>
		<category><![CDATA[Furan Tests]]></category>
		<category><![CDATA[Kva Dry Type Transformer]]></category>
		<category><![CDATA[Oil Filled Power Transformer]]></category>
		<category><![CDATA[Oil Transformer]]></category>
		<category><![CDATA[Power Distribution Equipment]]></category>
		<category><![CDATA[Power Factor Tests]]></category>

		<guid isPermaLink="false">http://www.powertransformersblog.com/?p=202</guid>
		<description><![CDATA[There are many technical reasons for using an oil filled power transformer or for using a dry type power transformer. But sometimes the reasons might be a bit of self interest. One example that MIDWEST runs into deals with customers that have a great need to monitor the condition of their power distribution equipment. There [...]]]></description>
			<content:encoded><![CDATA[<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-family: Arial; font-size: 11pt;">There are many technical reasons for using an <a title="Oil Filled Power Transformers For Sale" href="http://www.swgr.com/store/Oil-Filled-Transformer-Home.aspx">oil filled power transformer</a> or for using a <a title="Dry Type Power Transformers For Sale By MIDWEST" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">dry type power transformer</a>. But sometimes the reasons might be a bit of self interest. One example that <a title="Electrical Equipment For Sale by MIDWEST" href="http://www.swgr.com">MIDWEST</a> runs into deals with customers that have a great need to monitor the condition of their power distribution equipment. There may be many reasons for this. Some, certainly justified, say for a mission critical facility, and some less important. But for a <a title="Contact a MIDWEST Field Service Engineering Technician" href="http://www.swgr.com/Technical-Support-Options.aspx">MIDWEST field service engineering technician</a>, they would much rather test the dielectric fluid, oil, of a <a title="Transformers For Sale by MIDWEST" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">transformer</a> than go through the work of testing an equal Kva dry type transformer. <a title="Dry Type Transformers For Sale" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">Dry type transformers</a> have to be taken out of service and that usually means weekend or holiday work. Weekend or holiday work is not family friendly. It would take a technician maybe 10 minutes to sample the fluid in a<a title="2000 KVA Oil Filled Transformers For Sale" href="http://www.swgr.com/store/oil-filled-transformer.aspx/KVA/2000"> 2000 kva oil filled substation power transformer</a>, including a thorough technical and safety inspection of the transformer. The sample is turned over to the lab for a complete battery of tests. The results of these tests are very informative, especially when there is a history of test results. Lots of data and Electrical Power Engineers love lots of data. The <a title="Transformer Maintenance and Testing Services by MIDWEST" href="http://www.swgr.com/Services.aspx#TM">tests</a> may include a group of standard dielectric fluid tests, plus combustible gas-in-oil tests, furan tests, and power factor tests. And, of course, the ever important and super sophisticated smell and visual test performed by the experienced service technician on site.<span style="mso-spacerun: yes;">  </span>A nice technical package. The site inspection of the transformer by an experienced technician is extremely important.<span style="mso-spacerun: yes;">  </span>Whereas the visual inspection and dielectric tests performed on a <a title="2000 KVA Dry Transformer For Sale by MIDWEST" href="http://www.swgr.com/store/dry-type-high-transformer.aspx/KVA/2000">2000 kva dry transformer</a> have very limited value in real time or for historical data tracking. So, if the choice is 4 hours during a weekend or over a holiday versus 15 minutes during normal work hours and with much better information, the choice would be 15 minutes and the <a title="Oil Filled Transformers For Sale by MIDWEST" href="http://www.swgr.com/store/Oil-Filled-Transformer-Home.aspx">oil filled transformer</a>. </span></p>
]]></content:encoded>
			<wfw:commentRss>http://www.powertransformersblog.com/2011/09/technician%e2%80%99s-choice-oil-filled-power-transformer-versus-dry-type/feed/</wfw:commentRss>
		<slash:comments>1</slash:comments>
		</item>
		<item>
		<title>Can’t Store 15 Kv Air Cooled Transformers Outside</title>
		<link>http://www.powertransformersblog.com/2011/08/can%e2%80%99t-store-15-kv-air-cooled-transformers-outside/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=can%25e2%2580%2599t-store-15-kv-air-cooled-transformers-outside</link>
		<comments>http://www.powertransformersblog.com/2011/08/can%e2%80%99t-store-15-kv-air-cooled-transformers-outside/#comments</comments>
		<pubDate>Thu, 11 Aug 2011 17:17:03 +0000</pubDate>
		<dc:creator>MIDWEST</dc:creator>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[1000 KVA Dry Transformers]]></category>
		<category><![CDATA[15 KV Air Cooled Transformers]]></category>
		<category><![CDATA[dry type transformers]]></category>
		<category><![CDATA[General Purpose Transformers]]></category>
		<category><![CDATA[Nameplate Data]]></category>
		<category><![CDATA[Transformer Stored Outdoors]]></category>
		<category><![CDATA[Transformer Windings]]></category>
		<category><![CDATA[Used Dry Type Transformers]]></category>
		<category><![CDATA[Used Electrical Equipment]]></category>
		<category><![CDATA[Used Transformers]]></category>

		<guid isPermaLink="false">http://www.powertransformersblog.com/?p=197</guid>
		<description><![CDATA[MIDWEST frequently gets calls from someone wanting to sell used electrical equipment. We are very cautious of the biography of the equipment when the seller is someone other than the original owner. When there are any concerns, the equipment is shipped to MIDWEST, then thoroughly inspected and tested, before we consider purchasing. There are many [...]]]></description>
			<content:encoded><![CDATA[<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-family: Arial; font-size: 11pt;"><a title="Sellers and Buyers of Used Electrical Equipment" href="http://www.swgr.com">MIDWEST</a></span><span style="font-family: Arial; font-size: 11pt;"> frequently gets calls from someone wanting to sell <a title="Used Electrical Equipment For Sale by MIDWEST" href="http://www.swgr.com">used electrical equipment</a>. We are very cautious of the biography of the equipment when the seller is someone other than the original owner. When there are any concerns, the equipment is shipped to <a title="Sellers and Buyers of Used Electrical Equipment" href="http://www.swgr.com">MIDWEST</a>, then thoroughly inspected and tested, before we consider purchasing. There are many concerns relating to the condition of <a title="Used Electrical Equipment For Sale by MIDWEST" href="http://www.swgr.com">used electrical equipment</a>, so we may request pictures, prior use, nameplate data, and other details. Usually a visual inspection is the first line of rejection. With a little biographical information we can frequently determine that the equipment is scrap. As an example, we received a request to sell us three used 1000 kva 13,200 volt to 480/277 volt air cooled, <a title="Dry Type Transformers For Sale by MIDWEST" href="http://www.swgr.com/store/Dry-Type-High-Transformer-Home.aspx">dry type power transformers</a>. The seller was not the company that had used the <a title="Dry Type Transformers For Sale by MIDWEST" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">transformer</a> and the condition was described as “In great condition.” He said he had the <a title="Dry Transformers For Sale" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">transformers</a> for over two years and just wanted to sell them. We asked for pictures before shipping. We got the pictures and the <a title="Dry Type Power Transformers For Sale By MIDWEST" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">transformers</a> look great. No indications of structural damage. Paint condition indicated the transformers were probably used in a clean environment, a commercial building for example, rather than a manufacturing plant. But, the pictures showed the <a title="Dry Type Electrical Transformers For Sale" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">transformers</a> stored outdoors. Outdoors in the rain and whatever might blow into the windings. Immediate rejection. The windings would be wet and contaminated. Because of the location, the moisture in the windings would have frozen in the winter. The steel structure would be rusted. And if they stored these transformers outside, they had little knowledge of the proper handling of 15 kv dry type <a title="General Purpose Dry Type Transformers For Sale" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">general purpose transformers</a>. The pictures said it all. Junk.<span style="mso-spacerun: yes;">  </span></span></p>
]]></content:encoded>
			<wfw:commentRss>http://www.powertransformersblog.com/2011/08/can%e2%80%99t-store-15-kv-air-cooled-transformers-outside/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Electrical Transformer Voltage Taps Cause Open Circuit</title>
		<link>http://www.powertransformersblog.com/2011/07/electrical-transformer-voltage-taps-cause-open-circuit/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=electrical-transformer-voltage-taps-cause-open-circuit</link>
		<comments>http://www.powertransformersblog.com/2011/07/electrical-transformer-voltage-taps-cause-open-circuit/#comments</comments>
		<pubDate>Thu, 21 Jul 2011 17:05:06 +0000</pubDate>
		<dc:creator>MIDWEST</dc:creator>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[225 KVA General Purpose Dry Type Transformer]]></category>
		<category><![CDATA[480 Volts to 208 Volts]]></category>
		<category><![CDATA[Defective Transformer]]></category>
		<category><![CDATA[electrical transformer]]></category>
		<category><![CDATA[new transformer]]></category>
		<category><![CDATA[Open Circuit]]></category>
		<category><![CDATA[Poor Heating Connection]]></category>
		<category><![CDATA[power transformer]]></category>
		<category><![CDATA[reconditioned transformer]]></category>
		<category><![CDATA[Secondary Phases]]></category>
		<category><![CDATA[Tap Jumper]]></category>
		<category><![CDATA[Transformer Windings]]></category>
		<category><![CDATA[Turns Ratio Test]]></category>
		<category><![CDATA[Voltage Taps]]></category>

		<guid isPermaLink="false">http://www.powertransformersblog.com/?p=195</guid>
		<description><![CDATA[MIDWEST Engineering got a call from a plant supervisor that bought a 225 kva general purpose dry type power transformer, 480 volts to 208 volts. They had installed the transformer and energized it. But they swore they got no voltage at the secondary, 208 volt, side. The transformer was tested by MIDWEST before it was [...]]]></description>
			<content:encoded><![CDATA[<p><span style="font-family: Arial; font-size: 11pt; mso-fareast-font-family: 'Times New Roman'; mso-ansi-language: EN-US; mso-fareast-language: EN-US; mso-bidi-language: AR-SA;"><a title="Electrical Equipment For Sale by MIDWEST" href="http://www.swgr.com">MIDWEST</a> Engineering got a call from a plant supervisor that bought a 225 kva general purpose <a title="Dry Type Power Transformers For Sale By MIDWEST" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">dry type power transformer</a>, 480 volts to 208 volts. They had installed the transformer and energized it. But they swore they got no voltage at the secondary, 208 volt, side. The <a title="Transformers For Sale by MIDWEST" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">transformer</a> was tested by <a title="Power Transformer Experts" href="http://www.swgr.com">MIDWEST</a> before it was shipped, including being energized at full voltage. In addition, an inductive load was put on the transformer as part of our final testing procedure. But they were certain their <a title="Power Transformers For Sale" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">power transformer</a> had failed because they had just a couple volts at the output when energized at 480 volts on the primary. And they said they didn’t do anything to the defective transformer. So we ended up shipping them a second unit and asked them to send the suspect transformer back. When the suspect transformer arrived, the switchgear shop checked it out and found no visual indications of failure. If an <a title="Electrical Power Transformers For Sale" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">electrical power transformer</a> fails such that there is no voltage on any secondary phases, we would expect to find the failure during a visual inspection. In a <a title="New and Reconditioned Transformers For Sale" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">new or reconditioned electrical power transformer</a>, during a three phase fault, a lot of energy must go somewhere and it is usually pretty obvious. In this case there was absolutely nothing visual to indicate a failure. Our first transformer test, <a title="Turns Ratio Test Performed on Transformers by MIDWEST" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">turns ratio</a>, helped us find the problem immediately. The buyer had changed the transformer taps, but they did not remove the varnish on the unused tap tabs sticking out the side of the transformer windings. Sometimes these tabs are totally insulated with varnish and it has to be cleaned off thoroughly before connecting the tap jumper. This case was a little bizarre because the bolts holding the jumpers did not make contact on the inside of any of the holes in the insulated tap tabs. Pretty strange to not have any contact at any of the three jumpers.<span style="mso-spacerun: yes;">  </span>We have seen this problem before, but usually one or two of the tap jumpers makes some contact and a third is open.<span style="mso-spacerun: yes;">  </span>When changing taps, one needs to clean the jumpers and the taps so as to make sure there is a good current carrying connection. A poor heating connection can do some real damage and may not be noticeable until it’s too late. So, in a way, they got lucky.</span></p>
]]></content:encoded>
			<wfw:commentRss>http://www.powertransformersblog.com/2011/07/electrical-transformer-voltage-taps-cause-open-circuit/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Transformer Replacement will Often not be an Exact Replacement</title>
		<link>http://www.powertransformersblog.com/2011/07/transformer-replacement-will-often-not-be-an-exact-replacement/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=transformer-replacement-will-often-not-be-an-exact-replacement</link>
		<comments>http://www.powertransformersblog.com/2011/07/transformer-replacement-will-often-not-be-an-exact-replacement/#comments</comments>
		<pubDate>Fri, 08 Jul 2011 15:06:21 +0000</pubDate>
		<dc:creator>MIDWEST</dc:creator>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[Conventional Dry Type Transformer]]></category>
		<category><![CDATA[Dry Transformer]]></category>
		<category><![CDATA[Encapsulated Transformer]]></category>
		<category><![CDATA[fluid filled transformers]]></category>
		<category><![CDATA[Impedance]]></category>
		<category><![CDATA[Large Power Transformer]]></category>
		<category><![CDATA[Outdoor Transformers]]></category>
		<category><![CDATA[power transformers]]></category>
		<category><![CDATA[Primary Voltage]]></category>
		<category><![CDATA[Replace a Transformer]]></category>
		<category><![CDATA[Secondary Voltage]]></category>
		<category><![CDATA[Single Phase Transformers]]></category>
		<category><![CDATA[Spare Transformer]]></category>
		<category><![CDATA[Three Phase Transformers]]></category>
		<category><![CDATA[Transformer Nameplate]]></category>
		<category><![CDATA[Transformer Replacement]]></category>
		<category><![CDATA[transformers]]></category>

		<guid isPermaLink="false">http://www.powertransformersblog.com/?p=193</guid>
		<description><![CDATA[At MIDWEST we often get calls or receive inquiries from individuals or company employees seeking an exact transformer replacement for a particular unit.  The reasons are numerous.  Their existing transformer failed suddenly or they have a transformer that is in the process of failing.  Maybe they are trying to expand their facility with limited funds [...]]]></description>
			<content:encoded><![CDATA[<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-family: Arial; font-size: 11pt;">At <span style="color: blue;"><a title="Electrical Equipment For Sale by MIDWEST" href="http://www.swgr.com">MIDWEST</a></span><span style="color: blue;"> </span>we often get calls or receive inquiries from individuals or company employees seeking an exact <span style="color: blue;"><a title="Transformer Replacements For Sale by MIDWEST" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">transformer replacement</a></span> for a particular unit.<span style="mso-spacerun: yes;">  </span>The reasons are numerous.<span style="mso-spacerun: yes;">  </span>Their existing <span style="color: blue;"><a title="Power Transformers For Sale" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">transformer</a></span> failed suddenly or they have a <a title="Transformers For Sale by MIDWEST" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">transformer</a> that is in the process of failing.<span style="mso-spacerun: yes;">  </span>Maybe they are trying to expand their facility with limited funds and do not want to pay for the services of an engineering consultant.<span style="mso-spacerun: yes;">  </span>They look around and decide to copy what they already have and reason if they just had another one just like it and moved the walls out a bit, their newly purchased used machine ( another blog at another time) which hopefully will mean more income.<span style="mso-spacerun: yes;">  </span>Possibly the building has a new owner and they are looking for a <span style="color: blue;"><a title="Spare Transformers Available from MIDWEST" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">spare transformer</a></span> (a gold star to them for being pro-active).<span style="mso-spacerun: yes;">  </span>‘Finding another one just like it’ is easy if you are shopping for a jar of Jiff ® or Skippy®.<span style="mso-spacerun: yes;">  </span>But looking for running shoes just like the kind you purchased last year can be difficult.<span style="mso-spacerun: yes;">  </span>Now you can imagine just how difficult it is to locate an identical twin to <a title="Transformers For Sale" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">transformer</a> in a building over thirty years old, assuming the <span style="color: blue;"><a title="Call MIDWEST with you Transformer Nameplate Information" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">transformer nameplate</a></span> exists, is still legible and not covered with paint.<span style="mso-spacerun: yes;">  </span>If you are fortunate to have the model or type number, a Google search may yield a possible match. Hopefully it is an available unit for sale and not a line item on a specification for a future construction project.</span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-family: Arial; font-size: 11pt;"> </span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-family: Arial; font-size: 11pt;">A GOOGLE search with only the <a title="Power Transformers For Sale by MIDWEST" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">transformer</a> brand will help you find a soulmate who is usually looking for product data or a wiring diagram for that brand of transformer.<span style="mso-spacerun: yes;">  </span></span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-family: Arial; font-size: 11pt;">Sadly, some transformer companies are no longer in business, their assets were sold to another company, the factory shuttered and you trail runs cold.</span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-family: Arial; font-size: 11pt;"> </span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-family: Arial; font-size: 11pt;">Assuming the <a title="Transformers For Sale" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">transformer</a> was not built for an Arc furnace and is a one-of-a kind relic (see future blog) you can usually <a title="Replacement Transformers For Sale or Rent" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">replace a transformer</a> that was made by company X with a transformer that was manufactured by Company Y.<span style="mso-spacerun: yes;">  </span>To do so requires a complete list of specifications with all available information on the transformer whether you think it is relevant or not.<span style="mso-spacerun: yes;">  </span>There are a lot of parameters that need to be known: KVA, footprint, height and weight, impedance and most importantly the primary and secondary voltage and also if this is a <span style="color: blue;"><a title="Single Phase Transformers For Sale by MIDWEST" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">single phase</a></span> or <a title="Three Phase Transformers For Sale By MIDWEST" href="http://www.swgr.com/store/Transformer-SubCategory.aspx"><span style="color: blue;">three phase</span> transformer</a>.<span style="mso-spacerun: yes;">  </span>You also need to know where the transformer will be used (outdoors, indoors).<span style="mso-spacerun: yes;">  </span>If it is a <a title="Fluid Filled Transformers Available From MIDWEST" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">fluid filled</a> unit, what type of fluid?<span style="mso-spacerun: yes;">  </span>If it is a <a title="Dry Transformers For Sale" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">dry transformer</a> (<span style="color: blue;">conventional dry type</span> or <span style="color: blue;">encapsulated)</span>.<span style="mso-spacerun: yes;">  </span>You have to know if this transformer needs to have high side voltage taps and if the primary and secondary are Delta or Wye.<span style="mso-spacerun: yes;">  </span>If it is a <a title="Large Power Transformers For Sale" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">large power transformer</a>, where are the bushings and how are they arranged. Doing your homework first before you have the transformer shipped to you from another state will help you avoid the embarrassment, grief and additional charges that will rack up if the <a title="Replacement Transformers Available from MIDWEST" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">replacement transformer</a> arrives and it will not fit or is suitable for the application or you discover your cable stretcher is undersized.</span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"> </p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-family: Arial; font-size: 11pt;">by Vince</span></p>
]]></content:encoded>
			<wfw:commentRss>http://www.powertransformersblog.com/2011/07/transformer-replacement-will-often-not-be-an-exact-replacement/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>15 Second Test Reveals 1500 Kva Transformer Failure</title>
		<link>http://www.powertransformersblog.com/2011/06/15-second-test-reveals-1500-kva-transformer-failure/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=15-second-test-reveals-1500-kva-transformer-failure</link>
		<comments>http://www.powertransformersblog.com/2011/06/15-second-test-reveals-1500-kva-transformer-failure/#comments</comments>
		<pubDate>Fri, 03 Jun 2011 22:46:17 +0000</pubDate>
		<dc:creator>MIDWEST</dc:creator>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[1500 KVA Transformer]]></category>
		<category><![CDATA[dry type transformer]]></category>
		<category><![CDATA[high voltage windings]]></category>
		<category><![CDATA[rental transformers]]></category>
		<category><![CDATA[replacement transformer]]></category>
		<category><![CDATA[Switchgear]]></category>
		<category><![CDATA[transformer]]></category>

		<guid isPermaLink="false">http://www.powertransformersblog.com/?p=191</guid>
		<description><![CDATA[An Electrical Contractor called MIDWEST with an emergency. A customer lost a 1500 kva dry type power transformer. The voltage was 13,200 to 480.  Two of the fuses in the primary load break switch had blown. They checked things out and couldn’t find anything wrong, but wanted MIDWEST to test the transformer anyway. Meanwhile they [...]]]></description>
			<content:encoded><![CDATA[<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-family: Arial; font-size: 11pt;">An Electrical Contractor called <a title="Electrical Equipment For Sale by MIDWEST" href="http://www.swgr.com">MIDWEST</a> with an emergency. A customer lost a <a title="1500 KVA Transformers For Sale or Rent from MIDWEST" href="http://www.swgr.com/store/Dry-Type-High-Transformer/product/11-1190.aspx">1500 kva dry type power transformer</a>. The voltage was 13,200 to 480.<span style="mso-spacerun: yes;">  </span>Two of the fuses in the primary load break switch had blown. They checked things out and couldn’t find anything wrong, but wanted <a title="Electrical Equipment For Sale by MIDWEST" href="http://www.swgr.com">MIDWEST</a> to test the <a title="Transformers For Sale by MIDWEST" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">transformer</a> anyway. Meanwhile they checked out the secondary switchgear and a 480 volt to 208 volt <a title="Dry Type Transformers For Sale by MIDWEST" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">dry type transformer</a> in the same room as the <a title="Switchgear For Sale by MIDWEST" href="http://www.swgr.com/store/Switchgear-SubCategory.aspx">switchgear</a>. They found no smell and no smoke, so they figured they might get lucky, although we both knew that was not very probably.<span style="mso-spacerun: yes;">  </span>When 15kv, 100 amp fuses blow, a lot of energy went somewhere.<span style="mso-spacerun: yes;">  </span>The <a title="1500 KVA Transformers For Sale or Rent from MIDWEST" href="http://www.swgr.com/store/Dry-Type-High-Transformer/product/11-1190.aspx">1500 kva dry type transformer</a> was a typical indoor unit substation type, with LAs, cooling fans and a fan control package. When we got there, the electrical contractor already had the panels off the switchgear and transformer, and everything properly grounded.<span style="mso-spacerun: yes;">  </span>They offered to help haul up the test equipment, which is always nice, but we said to hold off for a minute.<span style="mso-spacerun: yes;">  </span>It took 15 seconds to get our flashlight and then it took another 15 seconds to inspect the <a title="Transformers For Sale" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">transformer</a> and tell them the transformer had failed and they needed to get a <a title="Replacement Transformers For Sale or Rent" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">replacement transformer</a> or a <a title="Rental Transformers available from MIDWEST" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">rental transformer</a>. Their skepticism was obvious, and for good reason. But we showed them the debris that had blown out the bottom of the center high voltage winding. Then had them look down through ventilation ports of the blown high voltage winding so they could see the blown out turns within the high voltage winding.<span style="mso-spacerun: yes;">  </span>They understood immediately.<span style="mso-spacerun: yes;">  </span>We ran a quick turns ratio test to document the failure. A case of seeing is believing. </span></p>
]]></content:encoded>
			<wfw:commentRss>http://www.powertransformersblog.com/2011/06/15-second-test-reveals-1500-kva-transformer-failure/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Electrical Power Transformer Mounting Feet</title>
		<link>http://www.powertransformersblog.com/2011/05/electrical-power-transformer-mounting-feet/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=electrical-power-transformer-mounting-feet</link>
		<comments>http://www.powertransformersblog.com/2011/05/electrical-power-transformer-mounting-feet/#comments</comments>
		<pubDate>Mon, 09 May 2011 18:15:12 +0000</pubDate>
		<dc:creator>MIDWEST</dc:creator>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[100 KVA Transformer]]></category>
		<category><![CDATA[1000 kva dry type transformer]]></category>
		<category><![CDATA[1500 KVA Transformer]]></category>
		<category><![CDATA[5000 KVA Dry Type Air Cooled Transformer]]></category>
		<category><![CDATA[Dry Type Electrical  Power Transformer]]></category>
		<category><![CDATA[electrical power transformer]]></category>
		<category><![CDATA[Excessive Mechanical Vibrations]]></category>
		<category><![CDATA[Mounting Bolts]]></category>
		<category><![CDATA[Mounting Feet]]></category>
		<category><![CDATA[new transformer]]></category>
		<category><![CDATA[Replace Failed Transformer]]></category>
		<category><![CDATA[Transformer Mounting Feet]]></category>
		<category><![CDATA[Vibration Dampening Pads]]></category>

		<guid isPermaLink="false">http://www.powertransformersblog.com/?p=188</guid>
		<description><![CDATA[MIDWEST had a customer who wanted to ask a question about a transformer but he said he was afraid we would laugh at him or think he was stupid. We assured him the only stupid questions are those not asked. He wanted to know if there was such a thing as transformer mounting feet. He [...]]]></description>
			<content:encoded><![CDATA[<p><a title="Electrical Equipment For Sale by MIDWEST" href="http://www.swgr.com">MIDWEST</a> had a customer who wanted to ask a question about a <a title="Transformers For Sale by MIDWEST" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">transformer</a> but he said he was afraid we would laugh at him or think he was stupid. We assured him the only stupid questions are those not asked. He wanted to know if there was such a thing as <a title="Transformers For Sale" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">transformer</a> mounting feet. He had checked the internet and didn’t find anything helpful. He was told by an engineer to make sure they removed the mounting feet from a <a title="New Transformers For Sale by MIDWEST" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">new transformer</a> their company had bought to <a title="Replacement Transformers For Sale or Rent" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">replace a failed transformer</a>. He was a purchasing agent and thought the engineer was trying to embarrass him so he didn’t ask any questions. He had rented a <a title="1500 KVA Transformers For Sale or Rent from MIDWEST" href="http://www.swgr.com/store/dry-type-high-transformer.aspx/KVA/1500">1500 kva electrical power transformer</a> from <a title="Electrical Equipment For Sale" href="http://www.swgr.com">MIDWEST</a> in the past and thought we could help him. And we did. <a title="Dry Type Electrical Transformers For Sale" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">Dry type electrical power transformers</a> have vibration dampening pads between the transformer mounting feet and the frame of the enclosure. These pads dampen the mechanical vibrations caused by the transformer. The mechanical vibrations cause sound vibrations, noise, which can be a problem. Excessive mechanical vibrations can cause a lot of trouble over time. And noise can be a huge negative human factor if people are working in the area. <a title="New Transformer Inventory by MIDWEST" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">New transformers</a> are shipped with mounting bolts between the transformer mounting feet and the frame of the transformer. Typically these mounting bolts go right through the vibration dampening pads. There are instructions for loosening or removing the mounting bolts such that the mounting bolts do not transfer the transformer vibrations to the enclosure. So, yes <a title="Dry Type Air Cooled Electrical Power Transformers For Sale or Rent" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">100 kva, 1000 kva and even 5000 kva dry type air cooled electrical power transformers</a> do have mounting feet. And yes the mounting bolts should be loosened or removed per the manufacturer’s instructions.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.powertransformersblog.com/2011/05/electrical-power-transformer-mounting-feet/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Power Transformer – Visible Defect at Top of Winding</title>
		<link>http://www.powertransformersblog.com/2011/04/power-transformer-%e2%80%93-visible-defect-at-top-of-winding/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=power-transformer-%25e2%2580%2593-visible-defect-at-top-of-winding</link>
		<comments>http://www.powertransformersblog.com/2011/04/power-transformer-%e2%80%93-visible-defect-at-top-of-winding/#comments</comments>
		<pubDate>Fri, 22 Apr 2011 23:46:40 +0000</pubDate>
		<dc:creator>MIDWEST</dc:creator>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[225 Kva 480 Volt Delta to 480/277 Volt Wye]]></category>
		<category><![CDATA[Dry Transformer]]></category>
		<category><![CDATA[Dry Type Electrical Transformer]]></category>
		<category><![CDATA[electrical power transformers]]></category>
		<category><![CDATA[electrical tests]]></category>
		<category><![CDATA[electrical transformer]]></category>
		<category><![CDATA[Insulation Resistance Test]]></category>
		<category><![CDATA[power transformer]]></category>
		<category><![CDATA[Primary Windings]]></category>
		<category><![CDATA[replacement transformer]]></category>
		<category><![CDATA[Taps of Transformers]]></category>
		<category><![CDATA[Turns Ration Test]]></category>
		<category><![CDATA[Winding Resistance Test]]></category>

		<guid isPermaLink="false">http://www.powertransformersblog.com/?p=183</guid>
		<description><![CDATA[MIDWEST frequently rejects equipment even thought it passes the electrical tests. Here’s an obvious example. MIDWEST’s Switchgear Shop rejected a 225 kva 480 volt delta to 480/277 volt wye dry type electrical transformer. We only had the core and coils, not the enclosure. The insulation resistance, winding resistance, and turns ration test results were all good. [...]]]></description>
			<content:encoded><![CDATA[<p class="MsoNormal" style="margin: 0in 0in 0pt;">
<div class="MsoNormal" style="margin: 0in 0in 0pt;"></div>
<p><span style="font-family: Arial; font-size: 11pt;"></p>
<div id="attachment_184" class="wp-caption alignleft" style="width: 310px"><a href="http://www.swgr.com/store/Transformer-SubCategory.aspx"><img class="size-medium wp-image-184" title="Power Transformers  Defect at Top of Winding" src="http://www.powertransformersblog.com/wp-content/uploads/2011/04/defectattopofwinding-300x225.jpg" alt="Power Transformers  Defect at Top of Winding" width="300" height="225" /></a><p class="wp-caption-text">Power Transformers Defect at Top of Winding</p></div>
<p class="MsoNormal" style="margin: 0in 0in 0pt;">MIDWEST <span style="font-family: Arial; font-size: 11pt;">frequently rejects equipment even thought it passes the electrical tests. Here’s an obvious example. <a title="Contact MIDWEST's Switchgear Div." href="http://www.swgr.com/Technical-Support-Options.aspx">MIDWEST’s Switchgear Shop</a> rejected a 225 kva 480 volt delta to 480/277 volt wye <a title="Dry Type Transformers For Sale by MIDWEST" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">dry type electrical transformer</a>. We only had the core and coils, not the enclosure. The insulation resistance, winding resistance, and turns ration test results were all good. The <a title="Electrical Transformers For Sale or Rent by MIDWEST" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">transformer</a> was energized at full primary voltage and had proper secondary voltage for the tap position. This all sounds good. So, why was the transformer classified scrap junk?  An inspection revealed the top two turns of the primary windings of one barrel had been crushed down. Something had been dropped onto these winding turns and pushed them down and separated them. The damage wasn’t physically dramatic. It was almost inconspicuous. But it was fatal to the transformer. In addition, this damage didn’t appear to have caused the fault that blew the fuses that resulted in the owner sending us the transformer to check it out. But we also found one of the ‘unused’ tap tabs was melted off to the point the bolt hole was completely gone. The end of the tab looked very clean. The <a title="Electrical Transformers For Sale or Rent by MIDWEST" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">transformer</a> was connected in a different tap. On top of all this, the side of the winding seemed blackened by an apparent arc blast. Apparently the bolted connection at this tap became loose and the arcing completely destroyed the tap connection. The taps of the transformer were changed in an effort to restore power until a <a title="Replacement Transformers Available from MIDWEST" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">replacement transformer</a> was installed. Sometimes the physical damage to <a title="Electrical Power Transformers For Sale" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">electrical power transformers</a> is very obvious. In this case, the damage to the electrical transformer was not as obvious as one might think.<span style="mso-spacerun: yes;">  </span>At least until after it was found. Test results alone can not be used to evaluate the condition of electrical dry type power transformers. The transformer must also be thoroughly inspected. What <a title="Electrical Equipment For Sale by MIDWEST" href="http://www.swgr.com">MIDWEST</a> calls a ‘hard focus’ inspection.</span></p>
<p></span></p>
]]></content:encoded>
			<wfw:commentRss>http://www.powertransformersblog.com/2011/04/power-transformer-%e2%80%93-visible-defect-at-top-of-winding/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>High Voltage Oil Filled Power Transformers Made with Wood – Surprise</title>
		<link>http://www.powertransformersblog.com/2011/04/high-voltage-oil-filled-power-transformers-made-with-wood-%e2%80%93-surprise/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=high-voltage-oil-filled-power-transformers-made-with-wood-%25e2%2580%2593-surprise</link>
		<comments>http://www.powertransformersblog.com/2011/04/high-voltage-oil-filled-power-transformers-made-with-wood-%e2%80%93-surprise/#comments</comments>
		<pubDate>Fri, 01 Apr 2011 18:44:52 +0000</pubDate>
		<dc:creator>MIDWEST</dc:creator>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[3750 KVA Oil Filled Transformer]]></category>
		<category><![CDATA[5 MVA Replacement Power Transformer]]></category>
		<category><![CDATA[5000 KVA Transformer]]></category>
		<category><![CDATA[High Voltage Oil Transformers]]></category>
		<category><![CDATA[Oil Filled Power Transformers Made with Wood]]></category>
		<category><![CDATA[power transformer]]></category>
		<category><![CDATA[replacement transformer]]></category>
		<category><![CDATA[Transformers Made with Wood]]></category>

		<guid isPermaLink="false">http://www.powertransformersblog.com/?p=181</guid>
		<description><![CDATA[MIDWEST was called to check out an old 3750 kva oil filled transformer. The owner was trying to decide whether to reclaim the oil in the old power transformer or to go ahead and replace it with a new 5000 Kva transformer. They actually needed a 5 Mva replacement power transformer. They had the history [...]]]></description>
			<content:encoded><![CDATA[<p><span style="font-family: Arial; font-size: 11pt; mso-fareast-font-family: 'Times New Roman'; mso-ansi-language: EN-US; mso-fareast-language: EN-US; mso-bidi-language: AR-SA;"><a title="Electrical Equipment For Sale by MIDWEST" href="http://www.swgr.com">MIDWEST</a></span><span style="font-family: Arial; font-size: 11pt; mso-fareast-font-family: 'Times New Roman'; mso-ansi-language: EN-US; mso-fareast-language: EN-US; mso-bidi-language: AR-SA;"> was called to check out an old <a title="3750 KVA Oil Filled Transformers For Sale by MIDWEST" href="http://www.swgr.com/store/oil-filled-transformer.aspx/KVA/3750">3750 kva oil filled transformer</a></span><span style="font-family: Arial; font-size: 11pt; mso-fareast-font-family: 'Times New Roman'; mso-ansi-language: EN-US; mso-fareast-language: EN-US; mso-bidi-language: AR-SA;">. The owner was trying to decide whether to reclaim the oil in the old <a title="Power Transformers For Sale" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">power transformer</a> or to go ahead and replace it with a new <a title="5000 KVA Oil Filled Transformer For Sale by MIDWEST" href="http://www.swgr.com/store/oil-filled-transformer.aspx/KVA/5000">5000 Kva transformer</a>. They actually needed a 5 Mva replacement power transformer. They had the history of the oil test results. It was apparent the <a title="Transformer For Sale" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">transformer</a> had slowly absorbed moisture over the years and there was serious paper degredation. They wanted <a title="Electrical Equipment For Sale by MIDWEST" href="http://www.swgr.com">MIDWEST</a> to do an under the cover inspection to see if there were visual signs of sludge and tank rust. Pretty straight forward stuff. Their electricians asked if they could look inside the transformer while we had the access cover open. They had to follow our safety precautions.<span style="mso-spacerun: yes;">  </span>They were absolutely amazed to see all the wood used inside the transformer. Almost the entire top of the core and coils was hidden under wood.<span style="mso-spacerun: yes;">  </span>The wood was used for blocking, for support of the tap changer, and for making the high voltage connects going to the line side of the windings. The electricians were a little skeptical when we explained how much wood was actually used in transformer construction. How common it was. And that 15 Kv high voltage terminations were made on the wood. They were also surprised how clean the inside of the <a title="Transformers For Sale by MIDWEST" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">transformer</a> looked, even though the oil was dark and there was visible sludge on flat surfaces, especially on the wood. For the electricians, seeing was believing. <a title="High Voltage Oil Filled Power Transformers for Sale" href="http://www.swgr.com/store/Oil-Filled-Transformer-Home.aspx">High voltage oil filled power transformers </a>are made with wood.</span></p>
]]></content:encoded>
			<wfw:commentRss>http://www.powertransformersblog.com/2011/04/high-voltage-oil-filled-power-transformers-made-with-wood-%e2%80%93-surprise/feed/</wfw:commentRss>
		<slash:comments>1</slash:comments>
		</item>
		<item>
		<title>Dry Type Air Cooled Electrical Transformers Outside – How Do They Survive</title>
		<link>http://www.powertransformersblog.com/2011/03/dry-type-air-cooled-electrical-transformers-outside-%e2%80%93-how-do-they-survive/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=dry-type-air-cooled-electrical-transformers-outside-%25e2%2580%2593-how-do-they-survive</link>
		<comments>http://www.powertransformersblog.com/2011/03/dry-type-air-cooled-electrical-transformers-outside-%e2%80%93-how-do-they-survive/#comments</comments>
		<pubDate>Fri, 25 Mar 2011 17:28:44 +0000</pubDate>
		<dc:creator>MIDWEST</dc:creator>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[15 Kv Transformers]]></category>
		<category><![CDATA[150 Air Cooled Transformer]]></category>
		<category><![CDATA[5 Kv Class Transformers]]></category>
		<category><![CDATA[50 Kva Transformer]]></category>
		<category><![CDATA[75 Kva Transformer]]></category>
		<category><![CDATA[air cooled transformer]]></category>
		<category><![CDATA[Electrical Power]]></category>
		<category><![CDATA[electrical power transformer]]></category>
		<category><![CDATA[electrical transformers]]></category>
		<category><![CDATA[Large Power Transformer]]></category>
		<category><![CDATA[Medium Voltage Outdoor Air Cooled Transformers]]></category>
		<category><![CDATA[Metal Enclosure]]></category>
		<category><![CDATA[Metal Shrouds]]></category>
		<category><![CDATA[Replacement Dry Type Transformer]]></category>
		<category><![CDATA[Weather Shields]]></category>

		<guid isPermaLink="false">http://www.powertransformersblog.com/?p=179</guid>
		<description><![CDATA[How does an air cooled or ventilated electrical power transformer located outside in the rain survive?  Why doesn’t the rain cause an electrical short? These are the occasional questions of someone who wants to replace an existing dry type or air cooled transformer with a larger power transformer, when the existing power transformer is located [...]]]></description>
			<content:encoded><![CDATA[<p><span style="font-family: Arial; font-size: 11pt; mso-fareast-font-family: 'Times New Roman'; mso-ansi-language: EN-US; mso-fareast-language: EN-US; mso-bidi-language: AR-SA;">How does an air cooled or ventilated <a title="Electrical Power Transformers For Sale" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">electrical power transformer</a> located outside in the rain survive?<span style="mso-spacerun: yes;">  </span>Why doesn’t the rain cause an electrical short? These are the occasional questions of someone who wants to <a title="Replacement Electrical Transformers For Sale" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">replace an existing dry type or air cooled transformer </a>with a larger power transformer, when the existing power transformer is located outside, exposed to the rain, wind and sometimes snow.<span style="mso-spacerun: yes;">  </span>It does look a little strange sometimes, but the <a title="General Purpose Dry Type Transformers For Sale" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">general purpose air cooled dry type electrical power transformers</a> are fitted with weather shields. They should be. If they are not, you will find out very quickly the first time it rains. The weather shields are metal shrouds, hoods, fastened over the upper vent openings. They prevent rain and snow from entering the top open vents of the <a title="Transformers For Sale by MIDWEST" href="http://www.swgr.com/store/Transformer-SubCategory.aspx">transformer</a>. This is true as long as the rain is falling vertical or possibly at a 45 degree angle. The rain or snow hits the weather shield and drips off rather than landing inside the metal enclosure of the air cooled power transformer.<span style="mso-spacerun: yes;">  </span>We do see these <a title="50 Kva Air Cooled Transformers For Sale" href="http://www.swgr.com/store/dry-type-low-transformer.aspx/KVA/50">50 kva</a>, <a title="75 Kva Air Cooled Transformers For Sale" href="http://www.swgr.com/store/dry-type-low-transformer.aspx/KVA/75">75 kva</a>, or even <a title="150 Kva Air Cooled Transformers For Sale" href="http://www.swgr.com/store/dry-type-low-transformer.aspx/KVA/150">150 kva air cooled transformers</a> fail. This really does not happen very often. And when it does, it’s usually because of a very unusual storm. Possibly where the wind is so strong, the rain is being driven almost sideways. More often we see failures due to snow filling the inside of the metal enclosure due to swirling and drifting of snow about and eventually inside the enclosure. We have seen this happen with 5 kv and even 15 kv class transformers. We are not fans of medium voltage outdoor air cooled transformers. As long as the enclosure remains intact, there should be no problem. And as long as there isn’t some unusual weather condition, they should be okay. In our business the term “should be” makes us cringe. When folks use the term “should be,” we think “sooner or later.”<span style="mso-spacerun: yes;">  </span>It’s healthy to be paranoid around electrical power.<span style="mso-spacerun: yes;">   </span></span></p>
]]></content:encoded>
			<wfw:commentRss>http://www.powertransformersblog.com/2011/03/dry-type-air-cooled-electrical-transformers-outside-%e2%80%93-how-do-they-survive/feed/</wfw:commentRss>
		<slash:comments>1</slash:comments>